The TS8000 has now been updated with DSI8000 software
version 345. This new build brings many new features and
enhancements to the power and functionality of the TS8000
HMI. Upgrading to this new version is easily accomplished
with the TS8000. If your PC is connected to the Internet,
just launch your current version of DSI8000. Once active,
select Help from the menu bar, and select Check For Updates
from the pull-down list. DSI8000 will then check for an
update and will prompt you for installation if one is found.
Several new TS8000 series products have been recently
introduced. Fieldbus option cards are now available for:
IEEE 1394 Firewire, CANopen, DeviceNet, and PROFIBUS DP. In
addition, the TS8000 is compatible with WAGO I/O Systems and
provides a remote I/O solution that can be controlled by the
HMI over Ethernet and CANopen networks.
Additionally, we are introducing a series of protective
clear film overlays for use in harsh environments. Available
for all four sizes of TS8000, the overlays are packaged in
bundles of 10. By use of a pre-applied low-tack adhesive,
application of the overlay is a snap!
Recently, Parker SSD Drives has announced new OEM
brand-label options on the TS8000 series. Units can be
ordered with custom three color overlays to suit individual
customer needs. For more information, call a member of the
Parker SSD Drives sales team. Minimum order quantities do
apply for OEM configurations.
The TS8000 is available in a wide array of popular sizes
and configurations: 3” Monochrome Pushbutton, 6” Color STN
Touchscreen, 8” Color DSTN Touchscreen, and 10.4” Color TFT
Touchscreen, for easy enclosure or operator console
mounting.

| Standard Hardware
Each TS8000 HMI ships standard with:
- (2) RS-232 Serial Ports
- (1) RS-485 Serial Port
- 10/100Mbps Ethernet Port
- Fieldbus Option Card Slot
- USB Programming Port
|
Standard Supported Protocols
- SSD Drives: 590+ DC, 650v AC, 690+ AC, AC890, and
LINK
- Allen Bradley: DF1 Serial, DH485, Ethernet I/P
- General Electric: SNP Serial, SRTP Ethernet
- Matsushita: FP Series
- Mitsubishi: A/Q/FX Serial, A/Q Ethernet
- Modicon: ModbusRTU/ASCII, TCP/IP
- Omron: C Series, FINS Master
- Parker: AcroloopController Serial, Compumotor6K
Serial and Ethernet
- PLC Direct: DirectNet, K Sequence Serial, UDP
Ethernet
- Siemens: S7 MPI and PPI Serial, TI500 Serial,
S7-300 Ethernet
- Telemechanique: Uni-Telway
|
* Other drivers include: Animatics, EZ Automation, Festo,
Giddings & Lewis, Hitachi, Honeywell, IDEC, KlocknerMoeller,
Toshiba, Yokogawa and more.
Optional Fieldbus Compatibility
Each TS8000 HMI comes standard with a Fieldbus Option
Card slot. This allows the user to integrate to one of
several popular Fieldbus networks, such as, IEEE 1394
Firewire, Link2, CANopen, DeviceNet*, and Profibus DP* .
In keeping current with popular Fieldbus topologies, the
TS8000 gives the user both flexibility and cutting-edge
compatibility in integration.
* The DeviceNet and Profibus DP option cards are slave
devices only –external 3rd party masters are required for
these topologies.
 |
8000/FA/00 -IEEE 1394 Firewire
- 400Mbps 1394A and 800Mbps 1394B CAT-5 Ports
- Fully compatible with all AC890 Firewire systems
- Allows remote programming and monitoring of 890’s
- 63 nodes / 100 meters (1394B).
|
 |
8000/LK/00 - Link2 Fiberoptic
- 2.7Mbps Fiberopticports
- Fully compatible with all Link2 systems
- Allows remote programming and monitoring of Link
- 3000 nodes / 60 meters.
|
 |
8000/CB/00 - CANopenMaster
- Supports data speeds up to 1Mbps
- Multi-master capable
- SDO DS-402 implementation
- 127 nodes / 1000 meters.
|
 |
8000/DN/00 - DeviceNet Slave
- Supports data speeds up to 500kbps
- Fully compatible with all ODVA DeviceNet master
nodes
- Polled I/O capable EDS based implementation
- 64 nodes / 500 meters.
|
 |
232FIELDBUS8000/PB/00 - Profibus DP Slave
- Supports data speeds up to 12Mbps
- Fully compatible with all Profibus DP master nodes
- Standard GSD based implementation
- 127 nodes / 100 meters.
|
|
|
RS-232 Serial |
RS-485 Serial |
| |
TS8000 Hardware |
Device Hardware |
TS8000 Hardware |
Device Hardware |
| 631 Servo |
Standard (RS-232 Port) |
Standard (X15 Port) |
Not Supported |
| 635 Servo |
Standard (RS-232 Port) |
Standard (COM1 Port) |
Standard (RS-485 Port) |
Optional (RP-485) |
| 635f Servo |
Standard (RS-232 Port) |
Standard (COM1 Port) |
Standard (RS-485 Port) |
Optional (RP-485) |
| 590+ DC Drive |
Standard (RS-232 Port) |
Standard (P3 Port) |
Standard (RS-485 Port) |
Optional (6513/00) |
| 650v AC Drive |
Standard (RS-232 Port) |
Standard (P3 Port) |
Standard (RS-485 Port) |
Optional (6055/EI00/00) |
| 690+ AC Drive |
Standard (RS-232 Port) |
Standard (P3 Port) |
Standard (RS-485 Port) |
Optional (6055/EI00/00) |
| LINK System |
Standard (RS-232 Port) |
Standard (RTNx Port) |
Not Supported |
| 890 |
Standard (RS-232 Port) |
Standard (HMI Port) |
Not Supported |
|
|
Ethernet |
CANopen |
| |
TS8000 Hardware |
Device Hardware |
TS8000 Hardware |
Device Hardware |
| 631 Servo |
Not Supported |
Optional (8000/CB/00) |
Standard (X20-21 Port) |
| 635 Servo |
Not Supported |
Optional (8000/CB/00) |
Optional (RP-CAN) |
| 635f Servo |
Not Supported |
Optional (8000/CB/00) |
Optional (RP-CAN) |
| 590+ DC Drive |
Standard (Ethernet Port) |
Optional (6055/ENET/00) |
Optional (8000/CB/00) |
Optional (6055/CAN/00) |
| 650v AC Drive |
Not Supported |
Not Supported |
| 690+ AC Drive |
Standard (Ethernet Port) |
Optional (6055/ENET/00) |
Optional (8000/CB/00) |
Optional (6055/CAN/00) |
| LINK System |
Standard (Ethernet Port) |
Optional (L5352) |
Not Supported |
| 890 |
Standard (Ethernet Port) |
Optional (8903/EN/00) |
Optional (8000/CB/00) |
Optional (8903/CB/00) |
|
|
Link RTN |
1394 Firewire |
| |
TS8000 Hardware |
Device Hardware |
TS8000 Hardware |
Device Hardware |
| 631 Servo |
Not Supported |
Not Supported |
| 635 Servo |
Not Supported |
Not Supported |
| 635f Servo |
Not Supported |
Not Supported |
| 590+ DC Drive |
Optional (8000/LK/00) |
Optional (6055/LINK/00) |
Not Supported |
| 650v AC Drive |
Not Supported |
Not Supported |
| 690+ AC Drive |
Optional (8000/LK/00) |
Optional (6055/LINK/00) |
Not Supported |
| LINK System |
Optional (8000/LK/00) |
Standard (RTNx Port) |
Not Supported |
| 890 |
Not Supported |
Optional (8000/FA/00) |
Optional (8903/FA/00) |
|
|
DeviceNet * |
Profibus DP * |
| |
TS8000 Hardware |
Device Hardware |
TS8000 Hardware |
Device Hardware |
| 631 Servo |
Not Supported |
Not Supported |
| 635 Servo |
Optional (8000/DN/00) |
Optional (RP-DEV) |
Optional (8000/PB/00) |
Optional (RP-PDP) |
| 635f Servo |
Optional (8000/DN/00) |
Optional (RP-DEV) |
Optional (8000/PB/00) |
Optional (RP-PDP) |
| 590+ DC Drive |
Optional (8000/DN/00) |
Optional (6055/DNET/00) |
Optional (8000/PB/00) |
Optional (6055/PROF/00) |
| 650v AC Drive |
Not Supported |
Optional (8000/PB/00) |
Optional (6513/PB) |
| 690+ AC Drive |
Optional (8000/DN/00) |
Optional (6055/DNET/00) |
Optional (8000/PB/00) |
Optional (6055/PROF/00) |
| LINK System |
Optional (8000/DN/00) |
Optional (L5351) |
Optional (8000/PB/00) |
Optional (L5353) |
| 890 |
Optional (8000/DN/00) |
Optional (8903/DN/00) |
Optional (8000/PB/00) |
Optional (8903/PB/00) |
* All SSD Drives hardware for DeviceNet and Profibus DP
are slave devices only – external 3rdparty masters are
required for these topologies.
- back to top
SSD Drives has introduced TS8000 - a new family of
web-enabled graphic operator interface stations poised to
revolutionize machine control.
TS8000 provides a user-friendly, powerful graphical HMI
touchscreen and much more. With over 30 popular PLC drivers
supported, built-in Ethernet, and direct communications with
all SSD Drives products, TS8000 has a handle on all your
drives system control needs.
TS8000 is available in 4 popular sizes: 3”, 6”, 8” and
10.4” for easy enclosure or console mounting.
WEB-ENABLED graphic operator interface stations
- On-board comms support for over
- 30 popular PLC Drivers
- Powerful graphic displays
|
- Direct Communications with all SSD Drive products
- Built-in Ethernet
- Remote monitoring and control
|
|
|

Programming Tools are FREE on the TS8000...no
extra charges!
Other High-end Touchpanel and SCADA systems may come
with only a very basic configuration software tool,
requiring you to purchase or license a costly graphic
design tool programming package, often with rates linked
to the number of tags used. TS8000 includes DSI8000, a
powerful graphic design and configuration software tool,
complete with PRE-ENGINEERED TEMPLATES that make HMI
design a snap! |
- back to top
DSI8000 leverages the enhanced communications power of
the TS8000 HMIs. Each HMI comes standard with 2 RS-232
ports, an RS-422/485 port, a 10/100BT Ethernet port, a USB
programming port, and an expansion slot for optional
Fieldbus communications cards. Flexible programming allows
for multiple ports to be active simultaneously. DSI8000
comes standard with communications drivers for all current
SSD Drives proudcts, such as the 590+ DC Drive, 650v and
690+ AC Drives, 631/635/637 Servo Drives, Link2 products,
and the new 890 Drive system. Additionally, device drivers
for most common PLC’s are included as well.
Standard Support For SSD Products
- EIBisync Drivers (590+, 650v, 690+)
- RTNx Drivers (890, Link Products)
- Servo Drivers (63x Family)
- RS-485 (Drive TechBox)
- Ethernet (Drive TechBox, Link Rack Card)
- back to top
 Each TS8000
features 5 comm ports, ready to accomodate many of
today's most popular protocol devices.
In addition, a COMMS EXPANSION MODULE slot provides
for additional Fieldbus options, including the
fiber-optic SSD LINK techbox, enabling the TS8000 to
provide its powerful HMI display graphics to SSD LINK
systems, with a wider choice of display sizes. |
|
|
 |
Central to DSI8000 is a powerful
graphical display editor. The display editor contains
many common drawing tools to aid in screen development.
In addition, DSI8000 provides a pre-defined symbol
library with over 4000 industrial control objects.
Easy To Program User Interface
- Uses standard HMI drawing tools
- Objects link to a common tag database
- Built in symbol library of common industrial
objects
- Object scripting enhances development power and
flexibility
|
Enhanced Program Editor
DSI8000 offers a built in C-based program editor to
further enhance application development. Use of the program
editor allows the developer to create more intricate custom
applications that process and pass data to and from the user
interface screens and the tag database. By using a C-based
structure, the user can take advantage of a common syntax
and programming structure.
Built In “C-Based” Scripting Language
Allows developer to use high level programming constructs
Enhances application functionality
Programming power allows TS8000 to “bridge the gap”
between touch panels and PC based SCADA systems.
Tag Database
DSI8000 incorporates an advanced tag database that allows
user to organize and individually customize communications
data. Data tags are configurable for: communications
mapping, data format, color and text definitions, multiple
alarm points, and event triggers. Properties set up in the
database are accessible throughout the DSI8000 development
tool. This is a central philosophy of DSI8000’s advanced
design environment.
- back to top
- English
- Spanish
- Dutch
- French
|
|
Unicode* Support for:
- Japanese
- Korean
- Chinese (Simplified and Trad.)
*(Unicode support requires Windows language packs to
be installed)
- back to top
SSD Drive’s
extraordinary DSI8000 Software – included
with every TS8000 – provides a multitude of exclusive
functions. Its sophistication also makes all the leading
edge capability of the TS8000 manageable, with user-friendly
drag and drop data mapping. DSI8000 works with all TS8000
HMIs. Initial set-up of DSI8000 is very easy and virtually
self-explanatory.
Flexible and easy to use software
...included with the TS8000
Fast and easy configuration and programming
DSI8000 is a powerful set of icon-based, configuration,
display, control, and data logging tools uniquely designed
to take full advantage of the TS8000 series architecture.
Most applications can be quickly set up using the
step-by-step process to configure communications protocols,
define data tags, and create a user-friendly interface.
A full complement of drag and drop graphical symbols
yield professional results in record time. Advanced features
such as programming, data logging, and configuring the
TS8000’s internal web server are intuitive and easily
enabled.
- back to top
The TS8000
offers both real-time trending, as well as historical data
logging for process application enhancement. Logged files
are stored in a common .CSV (comma separated variable)
format to the optional CompactFlash card. Trending and
logging functions are configured using DSI8000 in a simple
and easy to use manner. In addition, this stored data is
also accessible over the Web, by using a standard browser,
such as Internet Explorer.
Built in CompactFlash Support
With the addition of a commonly-available CompactFlash
card, memory is expanded and data can be permanently stored.
CompactFlash provides an easy method to clone, restore, and
upgrade applications.
- Uses common technology available to the consumer
- Expands available development memory
- Allows for permanent data storage
- Provides an easy method to clone, restore, and
upgrade applications
|
- back to top
 |
The DSI8000 web server is capable of
providing remote access to the TS8000 in several
different ways. You can use DSI8000 to automatically
generate lists of tags - each formatted according to the
tag’s properties. You can also create a custom web site,
using a third party HTML editor such as Microsoft
FrontPage, with code that instructs DSI8000 to insert
live tag values for realtime monitoring. In addition,
you can also enable DSI8000’s Virtual Panel, a unique
access and control feature, which allows a web browser
to both view and control the TS8000’s display in
realtime.
- Quickly create detailed Web pages with
manufacturing data
- Provides remote access and control of the HMI unit
- Allows manufacturing personnel to monitor
production data
|
- back to top
No more gateways! Perhaps the best feature
of the TS8000 is that it provides a bridge between devices
that are not capable of communicating directly with each
other. TS8000 achieves a low cost method integration of
existing hardware and automation components. |